Instructions of Operations and Functions for Generic Type of 3-stage Cord Switch for Heating Pad

 

 

 

 

 

 

 

 

 

 

 

 

 

♦️  Programming
 
High Temperature 100% Output  Red Light 60℃
 
Medium Temperature 65% Output  Violet Light 50℃
 
Low Temperature 35% Output   Blue Light 40℃
 
 
 
 
 I. Requirements of Input Power:
 
1、Rated Input Voltage:DC  5V (also can supply 3.7V or 7.4V or 9V or 12V) . 
 
2、 Rated Input Current:≤3A 
 
 
 
 II. Requirements of Output Power:
 
1、Output Voltage Range of Load:DC  5V (also can supply 3.7V or 7.4V or 9V or 12V) . 
 
2、Rated Output Current of Load: ≤3A
 
3、Single Way Output:Adjustment of Pulse Width
 
4、Auto Shutdown Time Timed:35 minutes
 
      (Time can be changed according to requirements of the customer.)
 
5、The wire length can be customized according to requirements of the customer.

 

 

III. Environment used

1、Temperature Range Used-10°C-- +55°C 

2、Humidity Range Used+10%-- +90% 

3、Temperature Range Stored-40°C-- +80°C

4、Humidity Range Stored+5%-- +95% 

5、Cooling Method Natural Cooling

 

 

 IV. Protective Function

 Reverse Connection Protection of Input Power with Power Reverse Connection Protection
 

 

 

V. Heating Pad

1、Size220*150mm
2、Power5V 10W  
 

 

 

 

 

 